All tools Print with PE stamp box Designed for sealed engineering submittals — print drops PE stamp + signature block at the end.

Terzaghi Bearing Capacity

Ultimate and allowable bearing capacity of shallow foundations on c-φ soils. Strip, square, and circular footings, with shape factors. Per Terzaghi (1943) with Vesić bearing-capacity factor formulas.

ft (= diameter for circular)
ft
psf
degrees
pcf
— (typically 3.0)
psf
psf

Defaults: 5-ft square footing, 3-ft embedment, c = 500 psf, φ = 30°, γ = 120 pcf, FS = 3 — typical sandy clay residential foundation.

Strip footing (general):
$$ q_{ult} = c \, N_c + q \, N_q + 0.5 \, \gamma \, B \, N_\gamma $$
With shape factors (sc, sq, sγ):
$$ q_{ult} = c \, N_c \, s_c + q \, N_q \, s_q + 0.5 \, \gamma \, B \, N_\gamma \, s_\gamma $$
Vesić bearing-capacity factors:
$$ N_q = e^{\pi \tan\phi} \, \tan^2\!\!\left(45 + \tfrac{\phi}{2}\right) $$
$$ N_c = (N_q - 1) \cot\phi, \qquad N_\gamma = 2(N_q + 1) \tan\phi $$
qult ultimate bearing capacity · c cohesion · q = γ × Df overburden pressure at footing base · γ soil unit weight below footing · B footing width (or diameter) · Nc, Nq, Nγ bearing-capacity factors (function of φ).

When Terzaghi applies

The Terzaghi bearing-capacity equation is for general shear failure of a shallow foundation with Df/B ≤ 1. For deeper foundations, use Meyerhof or Hansen with depth factors. For local-shear or punching failure (loose sand, soft clay), reduce φ to φ' = arctan(0.67 tan φ) and reduce c to 0.67c. The full Hansen and Vesić methods include depth, shape, inclination, ground, and base factors — this calculator implements only shape factors (the most common manual case).

Shape factors used here

Modern Hansen/Vesić shape factors depend on B/L and φ:

sc = 1 + (Nq/Nc)(B/L); sq = 1 + (B/L) tan φ; sγ = 1 − 0.4(B/L). For square or circular, B/L = 1. Use these for tighter estimates.

φ = 0 (clay) special case

For undrained analysis of saturated clay (φ = 0): Nc = 5.14, Nq = 1.0, Nγ = 0. The equation simplifies to qult = 5.14 cu sc + γ Df. For square footing on clay: qult ≈ 6.2 cu + γ Df. This is the classic short-term (undrained) bearing capacity check.

Factor of safety

Standard FS = 3 for both static dead load and live load. Some agencies require FS = 2.5 for total stress with high reliability soil data, or FS = 4 for poorly-defined parameters. For seismic-only loads, FS as low as 2 may be allowed (lateral seismic event is short-duration).

Settlement, not bearing capacity, often controls

For most working stress designs, allowable bearing pressure is limited by tolerable settlement (typically 1 in / 25 mm total) rather than ultimate capacity. A clean sand might have qult > 20 ksf but be limited by settlement to 4 ksf. Always check both. For foundations on stiff clay, qult/FS often governs.

Reference: Terzaghi, K. (1943). Theoretical Soil Mechanics. Wiley. Vesić, A.S. (1973). "Analysis of Ultimate Loads of Shallow Foundations." JSMFD ASCE, 99(SM1). Bowles, J.E. (1996). Foundation Analysis and Design, 5th ed., McGraw-Hill.

Related tools

Monthly engineering case studies

One real stormwater or hydraulics design problem per month, with the math worked out and the gotchas called out. No tutorials, no fluff.

Free. Unsubscribe anytime. Privacy.

Engineer of Record — Stamp & Signature
APPLY PE STAMP HERE
Engineer Name
License No.
State
Signature
Date
Project / Sheet
By stamping and signing, the Engineer of Record certifies that the inputs, formulas, and applicability of this calculation have been reviewed for the specific design context. PE-Calc tools provide computational support only — the engineer is responsible for verifying results, applying engineering judgment, and complying with applicable codes and standards.
Calculation generated at pe-calc.com