Tank Drain Time Calculator
Time to empty — or lower to any level — a vertical cylindrical or rectangular tank draining by gravity through a bottom orifice, from Torricelli's law with a discharge coefficient. Also reports the initial flow rate and the volume released.
Heads are measured from the orifice centreline to the water surface. Set h₂ = 0 to empty the tank. The orifice should be small relative to the tank for the quasi-steady assumption to hold.
Discharge coefficients for tank outlets
| Outlet | Cd |
|---|---|
| Sharp-edged orifice in a thin wall | 0.60 – 0.62 |
| Short square-edged tube (2–3 diameters long) | ≈ 0.80 |
| Re-entrant (Borda) tube, flowing free | ≈ 0.50 |
| Well-rounded bell-mouth entrance | 0.95 – 0.98 |
Typical textbook ranges. Coefficients vary with Reynolds number and edge condition; use a calibrated value where accuracy matters.
Worked examples
Example 1 — Emptying a vertical storage tank
Example 2 — The first half is the fast half
Example 3 — Rectangular basin (SI)
References: Brater, E.F., King, H.W., Lindell, J.E., Wei, C.Y. (1996). Handbook of Hydraulics, 7th ed., McGraw-Hill. Streeter, V.L., Wylie, E.B. (1985). Fluid Mechanics, 8th ed.
Common mistakes
- Using the tank’s total depth instead of the head above the outlet. Measure h from the centerline of the outlet. For an outlet in the side wall, water below it never drains.
- Using this formula with a pipe attached to the outlet. A long discharge line adds friction and minor losses and may run partly full. Then the outlet is not a free orifice and the drain time is longer.
- Applying it to a tank with a varying cross-section. The equation assumes constant plan area. Cones, spheres and horizontal cylinders need the area as a function of height, integrated numerically.
- Forgetting the air vent. A closed tank without venting builds vacuum as it drains and can stop flowing or collapse.
When this calculator doesn’t apply
This is Torricelli’s law integrated for free discharge through a small outlet, with constant Cd and no inflow. Tanks with inflow need level-pool routing. Very low heads, viscous liquids and outlets that vortex or draw air at the end of draining all slow the last part of the drawdown. For detention ponds with multi-stage outlets, use a reservoir routing calculation.