All dam-safety tools Print with PE stamp box Designed for sealed engineering submittals — print drops PE stamp + signature block at the end.

Ogee Spillway Discharge Calculator

Free-overflow discharge over an ogee-crest spillway per USACE EM 1110-2-1603. Computes the discharge coefficient C from the operating-head ratio He/Hd, applies pier and abutment contractions, and returns Q. Works for both vertical and sloped upstream faces.

ft
ft
ft
ft
——
——
—ft
—cfs

Defaults: vertical-face ogee with high approach (P/Hd = 3.3), no piers, rounded abutments, design head equals operating head.

$$ Q = C \cdot L_{\text{eff}} \cdot H_e^{3/2} \qquad L_{\text{eff}} = L - 2(N\cdot K_p + K_a)\cdot H_e $$
C discharge coefficient · L total crest length · Leff effective length after contractions · He operating total head (incl. velocity head) · Hd design head · Kp pier contraction · Ka abutment contraction · N # piers.

Cdesign for ogee crests at design head

USBR / USACE design discharge coefficient at He = Hd
P / HdCdesign (US)Cdesign (SI)
≥ 1.33 (high approach, vertical U/S face)4.032.225
1.003.952.18
0.503.782.09
0.203.551.96
≤ 0.10 (very low approach)3.201.77

Source: USACE EM 1110-2-1603 (1992), Plate 3-1; USBR Design of Small Dams (1987), Figure 9-23.

Off-design correction C / Cdesign

EM 1110-2-1603, Plate 3-2 — discharge coefficient ratio for He ≠ Hd
He/HdC / CdesignCrest pressure
0.200.83positive (separation)
0.400.89positive
0.600.93positive
0.800.97near atmospheric
1.001.00atmospheric (design)
1.201.03slightly sub-atmospheric
1.331.04typical upper design limit
1.501.06cavitation risk

Worked example

Example — vertical-face ogee at 25% above design head

Given: L = 50 ft, P = 20 ft, Hd = 6 ft, He = 7.5 ft, no piers, rounded abutments.
P/Hd = 20/6 = 3.33 → high approach, Cdesign = 4.03 (US)
He/Hd = 1.25 → C/Cdesign ≈ 1.035 → C ≈ 4.17
Leff = 50 − 0 = 50 ft (no contractions)
Q = 4.17 · 50 · 7.51.5 = 4.17 · 50 · 20.54
Q ≈ 4,283 cfs

References: USACE EM 1110-2-1603 (1992), Hydraulic Design of Spillways. USBR Design of Small Dams (1987), Chapter 9. Chow, V.T. (1959), Open-Channel Hydraulics, §14-7. Brater & King, Handbook of Hydraulics (7th ed. 1996).

Common mistakes

When this calculator doesn’t apply

The coefficients apply to standard WES ogee crest shapes with free flow. Gated crests at partial opening act as orifices, not weirs. Labyrinth, piano-key, broad-crested and stepped spillways have their own coefficients. Spillway capacity for a dam is a safety-critical calculation and should follow the governing agency’s procedures, often with physical or numerical model confirmation.

Related tools

Monthly engineering case studies

One real design problem per month. No tutorials, no fluff.

Free. Privacy.

Engineer of Record — Stamp & Signature
APPLYPE STAMPHERE
Engineer Name
License No.
State
Signature
Date
Project / Sheet
By stamping and signing, the Engineer of Record certifies that the inputs, formulas, and applicability of this calculation have been reviewed for the specific design context. PE-Calc tools provide computational support only — the engineer is responsible for verifying results, applying engineering judgment, and complying with applicable codes and standards.
Calculation generated at pe-calc.com