Parshall Flume Calculator

Free-flow discharge through a standard Parshall flume from the upstream measuring head, for every throat width from 1 inch to 50 feet, with an optional downstream head to check whether the flume is still in free flow.

ft
ft
ft³/s
gpm
MGD
L/s
%
%

Leave Hb blank or 0 if the flume discharges freely with no downstream gauge. Heads are referenced to the flume crest. Defaults: 2-ft flume, Ha = 1.5 ft, Hb = 0.9 ft (60% submerged — still free flow).

$$ Q = C\,H_a^{\,n} \qquad S = \frac{H_b}{H_a} $$
Q free-flow discharge (ft³/s) · Ha upstream measuring head in the converging section (ft) · Hb downstream head measured in the throat (ft) · C, n empirical constants for the throat width · S submergence ratio. Conversions: 1 ft³/s = 448.83 gpm = 0.64632 MGD = 28.317 L/s.

Parshall flume coefficients by throat width

Each standard size was calibrated separately (some of the largest by scale model), so C and n are not a smooth function of W and flumes must be built to the standard dimensions for their size. Coefficients below are USBR Table 8-6; submergence limits are from the same section.

Free-flow rating Q = C·Han (ft³/s, ft) and submergence limit
Throat width WCnQ at Ha = 1.0 ft (cfs)Free-flow limit Hb/Ha
1 in0.3381.550.33850%
2 in0.6761.550.67650%
3 in0.9921.550.99250%
6 in2.061.582.0660%
9 in3.071.533.0760%
1 ft3.951.553.9570%
2 ft8.001.558.0070%
3 ft12.001.5712.0070%
4 ft16.001.5816.0070%
5 ft20.001.5920.0070%
6 ft24.001.5924.0070%
7 ft28.001.6028.0070%
8 ft32.001.6132.0070%
10 ft39.381.6039.3880%
12 ft46.751.6046.7580%
15 ft57.811.6057.8180%
20 ft76.251.6076.2580%
25 ft94.691.6094.6980%
30 ft113.131.60113.1380%
40 ft150.001.60150.0080%
50 ft186.881.60186.8880%

Source: USBR Water Measurement Manual, 3rd ed., Chapter 8 §10, Table 8-6 and submergence limits. USBR lists the 8-ft flume at the boundary of both the 70% and 80% groups; this calculator uses the more conservative 70%. The 1-in flume passes 0.03 ft³/s at the minimum recommended head of 0.2 ft; below 0.2 ft, head-reading precision and surface tension degrade accuracy for flumes up to 1 ft wide.

Worked examples

Example 1 — 2-ft flume in an irrigation lateral

Given: W = 2 ft, Ha = 1.50 ft, Hb = 0.90 ft.
Q = 8.00 × 1.501.55 = 15.00 ft³/s
= 15.00 × 448.83 = 6,732 gpm = 9.69 MGD
S = 0.90/1.50 = 60% < 70% limit
Free flow — Q = 15.0 cfs is valid without correction

Example 2 — Checking the USBR manual's own values

The Water Measurement Manual's worked examples, reproduced from the equation:
3-in flume, Ha = 0.20 ft: Q = 0.992 × 0.201.55 = 0.0819 ft³/s (manual: 0.082)
3-ft flume, Ha = 2.10 ft: Q = 12.00 × 2.101.57 = 38.5 ft³/s (manual table: 38.4)
20-ft flume, Ha = 3.25 ft: Q = 76.25 × 3.251.60 = 502.6 ft³/s (manual table: about 503)
Equation and published tables agree to within 0.3%

Example 3 — When the flume is submerged

Given: W = 2 ft, Ha = 1.50 ft, Hb = 1.20 ft.
S = 1.20/1.50 = 80% > 70% limit
Submerged — the free-flow value of 15.0 cfs overstates the actual flow; apply the USBR submergence correction (Figure 8-16 for 1- to 8-ft flumes) or lower the tailwater

Parshall flume or long-throated flume?

USBR no longer generally recommends Parshall flumes for new installations. Long-throated (ramp or Replogle) flumes are cheaper to build, tolerate submergence up to about 90% with a single head reading, and can be rated by computer from as-built dimensions. Parshall flumes remain common because thousands are already in service and some state water laws and compacts require them. Designing a Parshall flume to operate submerged is poor practice: head-reading error adds 4–20% to the discharge uncertainty on top of the 3–5% free-flow accuracy.

References: U.S. Bureau of Reclamation (2001). Water Measurement Manual, 3rd ed., rev. reprint, Chapter 8, §10 Parshall Flumes. Parshall, R.L. (1950). Measuring Water in Irrigation Channels with Parshall Flumes and Small Weirs. USDA SCS Circular 843. ASTM D1941, Standard Test Method for Open Channel Flow Measurement of Water with the Parshall Flume.

Related tools

Monthly engineering case studies

One real stormwater or hydraulics design problem per month, with the math worked out and the gotchas called out. No tutorials, no fluff.

Free. Unsubscribe anytime. Privacy.

Engineer of Record — Stamp & Signature
APPLY PE STAMP HERE
Engineer Name
License No.
State
Signature
Date
Project / Sheet
By stamping and signing, the Engineer of Record certifies that the inputs, formulas, and applicability of this calculation have been reviewed for the specific design context. PE-Calc tools provide computational support only — the engineer is responsible for verifying results, applying engineering judgment, and complying with applicable codes and standards.