Water Properties by Temperature — Reference
Density, specific weight, dynamic and kinematic viscosity, and vapor pressure of fresh water at atmospheric pressure. These four properties feed nearly every hydraulic calculation — Reynolds number, friction loss, settling velocity, and pump NPSH.
The Four Values You Actually Look Up
| Property | SI (20°C) | US (60°F) | Where it is used |
|---|---|---|---|
| Density ρ | 998.2 kg/m³ | 1.938 slug/ft³ | Momentum, drag, Reynolds number |
| Specific weight γ | 9.789 kN/m³ | 62.37 lb/ft³ | Hydrostatic pressure, buoyancy, uplift |
| Kinematic viscosity ν | 1.003×10−6 m²/s | 1.21×10−5 ft²/s | Reynolds number, friction factor |
| Vapor pressure pv | 2.34 kPa abs | 0.256 psia | Cavitation, NPSH available |
SI Units — Fresh Water, 0 to 100°C
| T (°C) | ρ (kg/m³) | γ (kN/m³) | μ (×10−3 Pa·s) | ν (×10−6 m²/s) | pv (kPa abs) |
|---|---|---|---|---|---|
| 0 | 999.8 | 9.806 | 1.781 | 1.785 | 0.61 |
| 5 | 1000.0 | 9.807 | 1.518 | 1.519 | 0.87 |
| 10 | 999.7 | 9.804 | 1.307 | 1.306 | 1.23 |
| 15 | 999.1 | 9.798 | 1.139 | 1.139 | 1.70 |
| 20 | 998.2 | 9.789 | 1.002 | 1.003 | 2.34 |
| 25 | 997.0 | 9.777 | 0.890 | 0.893 | 3.17 |
| 30 | 995.7 | 9.764 | 0.798 | 0.800 | 4.24 |
| 40 | 992.2 | 9.730 | 0.653 | 0.658 | 7.38 |
| 50 | 988.0 | 9.689 | 0.547 | 0.553 | 12.33 |
| 60 | 983.2 | 9.642 | 0.466 | 0.474 | 19.92 |
| 70 | 977.8 | 9.589 | 0.404 | 0.413 | 31.16 |
| 80 | 971.8 | 9.530 | 0.354 | 0.364 | 47.34 |
| 90 | 965.3 | 9.466 | 0.315 | 0.326 | 70.10 |
| 100 | 958.4 | 9.399 | 0.282 | 0.294 | 101.33 |
US Customary — Fresh Water, 32 to 212°F
| T (°F) | ρ (slug/ft³) | γ (lb/ft³) | μ (×10−5 lb·s/ft²) | ν (×10−5 ft²/s) | pv (psia) |
|---|---|---|---|---|---|
| 32 | 1.940 | 62.42 | 3.732 | 1.924 | 0.0885 |
| 40 | 1.940 | 62.43 | 3.228 | 1.664 | 0.122 |
| 50 | 1.940 | 62.41 | 2.730 | 1.407 | 0.178 |
| 60 | 1.938 | 62.37 | 2.344 | 1.210 | 0.256 |
| 70 | 1.936 | 62.30 | 2.034 | 1.051 | 0.363 |
| 80 | 1.934 | 62.22 | 1.791 | 0.926 | 0.507 |
| 100 | 1.927 | 62.00 | 1.423 | 0.739 | 0.949 |
| 120 | 1.918 | 61.71 | 1.164 | 0.607 | 1.69 |
| 140 | 1.908 | 61.38 | 0.974 | 0.511 | 2.89 |
| 160 | 1.896 | 61.00 | 0.832 | 0.439 | 4.74 |
| 180 | 1.883 | 60.58 | 0.721 | 0.383 | 7.51 |
| 200 | 1.869 | 60.12 | 0.634 | 0.339 | 11.52 |
| 212 | 1.860 | 59.83 | 0.589 | 0.317 | 14.70 |
Relationships
Use g = 9.807 m/s² (32.17 ft/s²). Note the unit trap in US customary work: density is in slug/ft³, not lb/ft³. The familiar 62.4 lb/ft³ is specific weight γ, not density ρ. Mixing the two is the single most common error in US-unit fluid calculations — they differ by the factor g = 32.17.
Where Temperature Actually Changes the Answer
| Calculation | Property | Sensitivity |
|---|---|---|
| Hydrostatic pressure, uplift, buoyancy | γ | Negligible — under 1% across 0–30°C |
| Reynolds number, friction factor | ν | Strong — ν nearly halves from 5°C to 30°C |
| Pump NPSH available / cavitation | pv | Strong — pv rises ~5× from 5°C to 30°C |
| Particle settling (Stokes range) | μ | Strong — settling velocity scales as 1/μ |
Sources: White, F.M., Fluid Mechanics, Table A.1 (water properties). Munson, Young & Okiishi, Fundamentals of Fluid Mechanics, Tables B.1 and B.2. Vapor pressures follow the IAPWS-IF97 / NIST steam-table formulation. Values are for fresh water at atmospheric pressure; dissolved solids, and salinity in particular, shift density and vapor pressure and warrant source-specific data.
Worked example: where temperature matters and where it doesn’t
Pump suction at sea level: 10 ft static lift, 2 ft suction losses, water at 40°F vs. 80°F
Friction in 1,000 ft of 12-in lined pipe at 3 ft/s, ε = 0.0004 ft, same two temperatures
The two examples show where the full table earns its place. Viscosity changes a lot with temperature. But in turbulent flow through a pipe with any real roughness, the friction factor depends mostly on roughness, so the change in head loss is small. Viscosity matters much more in smooth pipe at lower Reynolds numbers, in laminar flow, and in settling, where velocity scales directly with 1/μ. Vapor pressure also matters at high elevation, with hot water, or wherever the NPSH margin is already thin.
Common mistakes
- Using 62.4 lb/ft³ where density belongs. In ρVD/μ and in momentum equations, US-unit density is 1.94 slug/ft³. Using 62.4 makes the answer 32.2 times too large.
- Reading μ and ν from different temperature rows, or from tables with different scale factors. The table headers above carry ×10⁻³ and ×10⁻⁵ multipliers. Missing one is an error of a factor of 1,000 or 100,000.
- Using gauge pressure with absolute vapor pressure. NPSH work needs both in absolute terms. At 5,000 ft of elevation, atmospheric pressure is about 12.2 psia, not 14.7.
- Applying fresh-water values to seawater or brine. Seawater is about 2.5% denser and slightly more viscous, enough to matter for ballast, buoyancy and density-driven flow.
When this card doesn’t apply
The tables are for pure fresh water at one atmosphere. Wastewater and stormwater are close enough for hydraulics. Sludges and slurries are not: they are non-Newtonian, and their viscosity depends on the shear rate. Water above 100°C, pressurized systems and steam need steam tables (IAPWS-IF97). Dissolved gases and suspended solids also change effective density and vapor behavior, which matters in pump suction design for treatment processes.
Related cheat sheets and tools
Kinematic viscosity from this card feeds the Reynolds number calculator and the flow-regime thresholds. Pair it with absolute roughness for Darcy-Weisbach head loss, or with the Stokes settling card for clarifier and grit-chamber design. Vapor pressure is the term you need for pump power and NPSH checks. For full network modeling, see HydroComplete.