Rebar Development Length — Reference
Straight tension development, ACI 318-19 simplified method (§25.4.2.3). Grade 60, normalweight concrete, uncoated bars, favorable spacing/cover case. Minimum ld = 12 in.
Bottom Bars, Grade 60 — ld in inches (rounded up)
| Bar | db (in) | f′c = 3,000 | f′c = 4,000 | f′c = 5,000 |
|---|---|---|---|---|
| #3 | 0.375 | 17 | 15 | 13 |
| #4 | 0.500 | 22 | 19 | 17 |
| #5 | 0.625 | 28 | 24 | 22 |
| #6 | 0.750 | 33 | 29 | 26 |
| #7 | 0.875 | 48 | 42 | 38 |
| #8 | 1.000 | 55 | 48 | 43 |
| #9 | 1.128 | 62 | 54 | 48 |
| #10 | 1.270 | 70 | 61 | 54 |
| #11 | 1.410 | 78 | 67 | 60 |
In bar diameters: 43.8/37.9/33.9·db (≤ #6) and 54.8/47.4/42.4·db (≥ #7) at 3,000/4,000/5,000 psi respectively. Note the jump from #6 to #7 — the code's two-tier equation, not a typo.
Modifiers
| Condition | Factor |
|---|---|
| Top bar (> 12″ fresh concrete below), Ψt | × 1.3 |
| Epoxy-coated, cover < 3db or spacing < 6db, Ψe | × 1.5 |
| Epoxy-coated, other, Ψe | × 1.2 |
| Lightweight concrete, λ = 0.75 | × 1.33 |
| Simplified-method unfavorable spacing/cover case | × 1.5 |
| Class B tension lap splice | 1.3 × ld |
Ψt·Ψe need not exceed 1.7. Favorable case requires: clear spacing ≥ db, clear cover ≥ db, and code-minimum stirrups over ld — or clear spacing ≥ 2db with cover ≥ db.
Sources: ACI 318-19, §25.4.2 (development), §25.5 (splices), Table 25.4.2.5 (modification factors). Wight & MacGregor, Reinforced Concrete: Mechanics and Design. Values computed for fy = 60,000 psi; Grade 80 bars scale by 80/60 plus additional ACI provisions.