All tools
Open bearing capacity calculator →

Presumptive Bearing Values — Reference

Allowable foundation pressures by soil class per IBC Table 1806.2, for use where the code permits design without a site-specific geotechnical investigation. Confirm local amendments — several states modify this table.

IBC Table 1806.2 — Presumptive Load-Bearing Values

Class of materialVertical bearing (psf)Lateral bearing (psf/ft depth)Lateral sliding
1. Crystalline bedrock12,0001,200μ = 0.70
2. Sedimentary & foliated rock4,000400μ = 0.35
3. Sandy gravel and/or gravel (GW, GP)3,000200μ = 0.35
4. Sand, silty sand, clayey sand, silty gravel, clayey gravel (SW, SP, SM, SC, GM, GC)2,000150μ = 0.25
5. Clay, sandy clay, silty clay, clayey silt, silt, sandy silt (CL, ML, MH, CH)1,500100cohesion 130 psf

Sliding: friction coefficient μ applies to dead load for classes 1–4; for class 5, cohesion times contact area, not to exceed one-half the dead load. Mud, organic silt, organic clays, peat, and unprepared fill have no presumptive capacity — investigation required (IBC 1806.2 footnotes).

Presumptive means "absent better information." These values are screening-level and deliberately low. A geotechnical investigation routinely doubles or triples usable bearing on decent soils, pays for itself on anything bigger than light-frame construction, and is mandatory where soils are questionable, expansive, or saturated (IBC 1803). The values here are the floor, not the target.

Quick Screening Numbers

SituationWorking number
Continuous wall footing, 1,500 psf soil, 8-ft wall≈ 16″–24″ wide
Column on 2,000 psf soil, 40 kip service load≈ 4.5 ft × 4.5 ft
Minimum footing depth (frost, typical mid-Atlantic/Southeast)12″–36″ per local code

Screening only — size from actual loads with the bearing capacity tool or the geotech report's allowable pressure.

Sources: 2021 International Building Code, §1806 and Table 1806.2 (ICC). Soil classifications per ASTM D2487 (USCS). Check state/local amendments — the table is frequently modified.

Computing ultimate capacity instead? Terzaghi bearing capacity → · Settlement? Consolidation tool. · Want the whole set? Print all 38 cards →

Worked example: column footing on presumptive values

40-kip service column load on Class 4 soil (2,000 psf), footing 1.5 ft thick with 1.5 ft of soil cover

Find whether the 4.5-ft square footing from the screening table works once its own weight is counted
Footing weight: 4.5 × 4.5 × 1.5 ft × 150 pcf = 4.56 kip; soil cover 4.5 × 4.5 × 1.5 × 120 pcf = 3.65 kip
Bearing pressure: (40 + 4.56 + 3.65) × 1,000 / 20.25 ft² = 2,380 psf, which is more than 2,000 psf
Required width with self-weight: B = √(40,000 / (2,000 − 225 − 180)) = 5.01 ft → use 5′-3″
Check 5.25 ft: (40 + 6.20 + 4.96) × 1,000 / 27.56 = 1,856 psf ≤ 2,000 psf

The screening table’s 4.5-ft footing ignores the weight of the footing and the backfill. On a 40-kip column that weight is about 20% of the load, enough to push bearing over the allowable value. For sliding on the same Class 4 soil, μ = 0.25 times the dead load gives the resistance. With 30 kip of dead load that is 7.5 kip. On Class 5 clay, cohesion of 130 psf on a 4.5-ft footing gives only 2.6 kip. Clay footings that carry lateral load usually need a key or passive resistance.

Common mistakes

When this card doesn’t apply

IBC 1806 values are permitted only where the building official does not require a geotechnical investigation. Expansive soils, collapsible soils, high groundwater, slopes and structures on previously filled sites all trigger IBC 1803 investigation requirements. Settlement is not checked by presumptive values at all. Retaining walls, dams and heavily loaded or vibrating foundations need site-specific geotechnical design. For residential work, IRC Table R401.4.1 has its own, similar presumptive values.

Related cheat sheets and tools

Pair with the unit weights card for dead-load takeoffs, the Terzaghi bearing capacity factors (Nc, Nq, Nγ) table behind the computed value, the Terzaghi bearing capacity tool for computed capacity, and the Rankine earth pressure tool for wall design.

Get future cheat sheets in your inbox

One reference card or worked-example case study per month, delivered the moment it's published. Free.

Free. Unsubscribe anytime. Privacy.